WHX Cape Town 2025German Exhibitors Königsee Implantate GmbH

Königsee Implantate GmbH

Booth number: H3.D28
www.koenigsee-implantate.de/

About us

Königsee Implants is one of the leading German medical technology companies in the field of osteosynthesis. For over 30 years, our company has been developing, producing and distributing implants and instruments for traumatology and orthopaedics. The motivation of our daily work aims at the development and optimisation of health-promoting Products always with the patient’s well-being in mind. With our innovative products for almost all bone sections – from the collarbone to the toes – we actively shorten the healing process of fractures compared to conventional treatment methods, which ideally reduces both the costs for the clinic and the burden for the patient.

Address

Königsee Implantate GmbH
OT Aschau, Am Sand 4
07426 Allendorf
Germany

E-mail: info@koenigsee-implantate.de
Phone:  +49 36738 4980
Internet: www.koenigsee-implantate.de/

Contact person:

Frank Orschler
CEO
E-mail: frank.orschler@koenigsee-implantate.de

Products & Services

We supply implants MADE IN GERMANY – from clavicle to foot. The products we produce in Germany and sell worldwide are especially designed to suit the needs of osteosynthesis and guarantee both doctor and patient alike a smooth surgical procedure with the aim to improving the patient’s quality of life.

HTO plate 6.0 /4.5 as medial

The angle-stable HTO (High Tibial Osteotomy) plate with 3 head holes for 6.0 cancellous screws is used for stabilisation after a high valgus tibial osteotomy.

Visit website

Distal radius plate 2.4 Watershed vas

The anatomically configured Watershed versions with steep palmar adjustment angle to allow positioning under the Watershed line and to protect flexion, features a flattened plate end so the plate can be inserted with minimum damage to tissue.

Visit website

Proximal Humerus Plate Eight double threaded 4.0/3.5 variable angle stable

This implant was designed with a focus on providing a precise anatomical fit and the ideal diverging screw position in the area of the humeral head.

Visit website

TIS™ screw 7.5 thread 32 back tapping; self drilling; self tapping;

The cannulated and fenestrated TIS™ screws enable precise and measured cementing in osteoporotic bone after checking the screw position. Depending on the required compression in the fracture or joint gap, a choice can be made between fully or partially threaded screws - for a customised, stable restoration.

Visit website

Patella plate 3.5 vas

A patella fracture results in an interruption of continuity in the stretch flex mechanism and the incongruity of the patellofemoral articulation. Thereby, in addition to restoring the extensor mechanism and achieving a smooth joint surface, the goals of surgical treatment also include undisturbed fracture healing as well as a stable fixation for early functional exercise treatment to maintain joint function.
The development of the variable stable angle patella plate introduced the principle of internal fixation, which is used for the treatment of patella fractures.

Visit website

My German Pavilion

  • Manage your personal profile here and enter your desired business contacts to German companies
  • Keep an eye on the trade fairs, German exhibitors and products that are of interest to you
  • Receive an e-mail notification on relevant upcoming German trade fair presentations
Sign up now